Blast Resistant Door Type

YEMEN LANG Project(Sliding Blast Resistant Door -1.79bar)
Sliding Blast Resistant Door (Qatar Armed Forces Project 5.73 BAR)
The First Fleet of R.O.K Navy
(Inspection Team)
(해군1함대 감시대)
Hyundai Oil Bank
Gunsan Battery Stabilization Center Project(JIAT)
(군산 배터리 안정화센타)
ADD(국방과학연구소)
거아도 Sliding Blast Resistant Door
Concrete Type Blast Resistant Door (3Bar)
00設施 化生防機械室出入口
Steel Type Blast Resistant Door (3Bar)
現代精油(株) PCB出入口 entrance
Steel Type Blast Resistant Door (100Bar)
00設施 彈藥庫出入口
Steel Type Blast Resistant Door
Embeddment plate 94-5951 陸上設施 化生防 處理室
S-OIL(溫山工廠)
NHC 防暴門

國防科學研究所 (ADD, 40 Bar) / INPA TUNNEL / Darakdae Firing Range

1. Design Criteria

1.1) Pressure Release

1.1.1) Internal pressure at the beginning
    b = 12.67 bar = 186.2 psi

1.1.2) Internal pressure at the end
    b = 1.0 bar = 14.7 psi

1.1.3) Duration of the pressure release from start
    to end
    T = 8.04 second

1.2) Property of the 19.0 thick steel plate.
    Consider 12inches wide strip of the calculation
    S = bd2 / 6 = 12 * 0.752 / 6 = 1.125 in3
    I = bd3 / 12 = 12 * 0.753 / 12 = 0.422 in4
1.3) Wide of Doors L= 36.0 inch

2. Calculation of the bending stress and Deflection

2.1) Bending moment and stress of the steel plate
Assume pressure shall be linearly released at the speed
of 0.5 seconds interval over the entire pressure release

2.1.1) Uniform pressure release
    W = 12 (186.2-14.7)/(8.04/0.5)= 128 lbs/in/0.5 second

2.1.2) Bending moment V
    M = wL2/8 = 128 * 362/8 = 20,736 in-ibs

2.1.3) Bending stress
    f= M/S = 20,736/1.125 = 18,432 lbs/in2
    = 18.432ksi < 0.6*36(=21.6ksi) : O.K

2.1.4) Deflection of the plate = 5wL4/384EI
    = 5*128*364/(384*29000000*0.422)
    = 0.228 in = L/157 < L/120 : O.K

3. Conclusion

Based on the result of the calculation, the thickness of the plate, 19 mm for the Blast resistant doors are adequate.