Overview & Application

Ref. Document

– ACI 318-99/02/05
– SHQAM(SAMHOON QUALITY ASSURANCE MANUAL)
– Test Report for ASTM F 2247(SSW/367/2012 Rev.7 dated 28. 8.2015/15.7 PSI)
– Test Report for Blast Valve(LRS-37844/2011/ 3 BAR)
– SAMHOON Qatar Sliding Blast Protection Door SSD-01, Blast Simulation Analysis Report
#480-BAR-R20211223 |Release: R6, December, 23rd, 2021
– SAMHOON Qatar Swing Blast Protection Door SD08, Blast Simulation Analysis Report
#480BARR20211027|Release:R2,November, 11th, 2021
– ASCE 9th : Blast Resistant Design of Buildings
– Planning Guideline for Chemical Warfare Defense Military Facility
– TM5-1300 : Structures to Resist Effects of Accidental Explosions
– TM5 855-1 : Fundaments of Protective Design for Conventional Weapons
– TM5 858-1 : Design Facilities to Resist Nuclear Weapon Effects ; Facilities System Engineering
– TM5 858-2 : Design Facilities to Resist Nuclear Weapon Effects
– TM5 858-3 : Design Facilities to Resist Nuclear Weapon Effects ; Structures
– TM5 858-5 : Design Facilities to Resist Nuclear Weapon Effects ; Air Entrainment, Fasteners, etc.
– TM5 858-6 : Design Facilities to Resist Nuclear Weapon Effects ; Hardness Verification
– TM5 858-7 : Design Facilities to Resist Nuclear Weapon Effects ; Facility Support Systems
– TM5 858-8 : Design Facilities to Resist Nuclear Weapon Effects ; Illustrative Examples
– UFC 3-340-02(STRUCTURES TO RESIST THE EFFECTS OF ACCIDENTAL EXPLOSIONS)
– ASTM F 2247(Standard Test Method for Metal Doors Used in Blast Resistant Applications Equivalent Static Load Method)
– ASTM E 283(Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen)
– AWS D1.1 : STRUCTURAL WELDING – STEEL
– CNC Test Report(Explosion Proof Glass Structure Test-071119)
– MIL-STD-901D : 2 BAR 와3 BAR에 대한 부유식 충격시험기의 충격응답해석2 BAR & 3 BAR Shock Response Analysis of MIL-S-901D Floating Shock PlatformStandards & Codes

Drawings, Data and Procedures

a. Certification of Design Report
b. Quality assurance and quality control program
c. Erection information
d. Detail shop drawings
e. Manufacturer’s Specifications
f. Shop welding methods and procedure
g. Air Tight Test procedure
h. Post weld heat treatment procedure
i. Certified Material Test Report(CMTR)
j. Non-destructive examination procedure
k. Spare parts list
l. Handling, storage instruction

ARMY Part

일부 제품사진을 확인하시면 관련 참고도면을 보실수 있습니다

HD HHI 전동식 슬라이딩 방폭문(4BAR)

LPD UAE AL-MARYAH04 BLAST DOOR (3BAR)

Blast Sliding Door (U.S.ARMY Kunsan Airport 8th Fleet of USFK)

Igloo Blast Sliding Door - US Army ECMs in AHA No. 25 Camp Casey Project (7 BAR)

The US Japan Armed Forces FED (주일 미군) / Stainless Steel Door / Typhoon rate / 7.65KPa

Blast Proof Door( India project )
Magazine Project(100bar)
NCD MCR Entrance
EMBEDD PLATE

Turkmenistan President Palace Project(12 BAR)

CP-Tango Project (Max. 35 BAR)

Cladding Project Site(15,000mm x 6,200mm, 30 BAR)

Double Swing Blast Door (Project B-FM Phase In Singapore(36 BAR, 6.0M x 5.5M))

Custom Blast Doors-(CBR) Vertical Load Acting(363Psi) 4.0M x 8.0m)

Blast & Gas Tight Door(8.0 bar/ASTM E 283)/ SEONGNAM City Hall CBRNe Facilities

Nuclear Power Plant

Steel type Blast & Air Leakage Door
Steel type Blast & Air Leakage Door
월성 원자력 발전소 (삼중수소제거실 방폭 및 기밀문)
방폭문 성능평가 시험 한국기계연구원-ANSI N510
방폭문 성능평가 시험 한국기계연구원-ANSI N510
방폭문 설치 울진원자력 발전소 3 & 4호기
Steel Type Blast Door(3Bar) 94-5951 육상시설 화생방 처리실
콘크리트 형식 방폭문
Concrete Type Blast Door (3Bar) 대전시청사 화생방시설

OIL, LNG Part

PEMEX INATITLAN ALKYLATION in Mexico (12.5 PSI)
Blast Proof Door 30kpa(SAKHALIN II PROJECT PHASE2-LNG PLANT)
Blast Proof Door( India project )
Hyundai Oilbank PCD EntranceAuto/Manual Type Blast Door(3Bar)
S-OIL(Onsan Factory)NHC Blast Door (7.8psi)
Blast Window2.02 psi pressure & 1 hr Fire rate
방화 및 방폭도어 (2hr fire-rate) (쿠웨이트오일)
Restraining Hinge / Krcc Yosu Plant / Blast Load 7.5 PSI
Blast Proof (13PSI, IMPULSE OF 1,100PSI-MS)
3hr Fire Rate Door
Arzew Refinery Rehabilitation and Adaptation Project (Arzew)
Blast Resistant and Gas Tight Doors(1.0 BAR)
Hyundai Oilbank(23kPa)
GA PJT_JV Battery Plant / USA
친환경 농기계 부품시험동(농업진흥원)

YEMEN LNG(YLNG) Blast Proof & Gas Tight Doors(1.75 Bar)​

YLNG Upstream Project - Phase II, Blast Resistant and 2hr Fire Rate Doors and Windows(4.5 PSI)

HQ ISAF Project / Kabul, Afghanistan Blast & Bullet Resistant Door and Windows(30 kPa/AK 47)