Report

Wind Load System Calculation

1. Wind Load : P=30 psf = 0.00146 kg/cm2

2. Design requirement : Hang down value must be below L/180.

3. The load to slot equally distributed load

ⓐ Slot Wide 7.4 cm
ⓑ Equally distributed load
W= 0.0146 kg/cm2 * 7.4cm = 0.10804 kg/cm

4. Features of Slot material

A) a. Elastic modulus of Slot material E=2.12*106
b. Slot material profile 2nd moment
ⓐ In case thickness of Slot material is 1.6 mm: 20cm4
ⓑ In case thickness of Slot material is 1.2 mm: 14cm4
③ simple beam’s maximum hang down value = 3WL4 / 384 EI.
④ Door Wide to fulfill the design requirement
L/180 = 5WL4/ 384EI
L= √384EI/180*5W
s= √384*2.12*106**20/180*5*0.10804
L= 551.18cm = 18.083 ft

B) ① In case thickness of Slot material is 1.2 mm
② Design standards
ⓐ Slot = simple beam
ⓑ L = The maximum width of Door
③ simple beam’s maximum hang down value = 5WL4 / 192 EI.
④ Door Wide to fulfill the design requirement
L/180 = 5WL4/ 192EI
L= √192EI/180*W
s= √192*2.12*106**14*16/180*0.10804
L= 1673.69cm = 54.911 ft

CONCLUSION

If Door width is 18′-8″ ~ 54′-91″, it is manufactured as 1.2mm Slot, and a Windload system is installed.

If Door width is over 54′-8″, a Windload system is not installed.