– ACI 318-99/02/05 – SHQAM(SAMHOON QUALITY ASSURANCE MANUAL) – Test Report for ASTM F 2247(SSW/367/2012 Rev.7 dated 28. 8.2015/15.7 PSI) – Test Report for Blast Valve(LRS-37844/2011/ 3 BAR) – SAMHOON Qatar Sliding Blast Protection Door SSD-01, Blast Simulation Analysis Report #480-BAR-R20211223 |Release: R6, December, 23rd, 2021 – SAMHOON Qatar Swing Blast Protection Door SD08, Blast Simulation Analysis Report #480BARR20211027|Release:R2,November, 11th, 2021 – ASCE 9th : Blast Resistant Design of Buildings – Planning Guideline for Chemical Warfare Defense Military Facility – TM5-1300 : Structures to Resist Effects of Accidental Explosions – TM5 855-1 : Fundaments of Protective Design for Conventional Weapons – TM5 858-1 : Design Facilities to Resist Nuclear Weapon Effects ; Facilities System Engineering – TM5 858-2 : Design Facilities to Resist Nuclear Weapon Effects – TM5 858-3 : Design Facilities to Resist Nuclear Weapon Effects ; Structures – TM5 858-5 : Design Facilities to Resist Nuclear Weapon Effects ; Air Entrainment, Fasteners, etc. – TM5 858-6 : Design Facilities to Resist Nuclear Weapon Effects ; Hardness Verification – TM5 858-7 : Design Facilities to Resist Nuclear Weapon Effects ; Facility Support Systems – TM5 858-8 : Design Facilities to Resist Nuclear Weapon Effects ; Illustrative Examples – UFC 3-340-02(STRUCTURES TO RESIST THE EFFECTS OF ACCIDENTAL EXPLOSIONS) – ASTM F 2247(Standard Test Method for Metal Doors Used in Blast Resistant Applications Equivalent Static Load Method) – ASTM E 283(Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen) – AWS D1.1 : STRUCTURAL WELDING – STEEL – CNC Test Report(Explosion Proof Glass Structure Test-071119) – MIL-STD-901D : 2 BAR 와3 BAR에 대한 부유식 충격시험기의 충격응답해석2 BAR & 3 BAR Shock Response Analysis of MIL-S-901D Floating Shock PlatformStandards & Codes
Drawings, Data and Procedures
a. Certification of Design Report b. Quality assurance and quality control program c. Erection information d. Detail shop drawings e. Manufacturer’s Specifications f. Shop welding methods and procedure g. Air Tight Test procedure h. Post weld heat treatment procedure i. Certified Material Test Report(CMTR) j. Non-destructive examination procedure k. Spare parts list l. Handling, storage instruction
ARMY Part
You can find reference drawings through checking photos of some products.
HD HHI P-180 Blast Protection Sliding Doors(4BAR)
HD HHI P-180 Blast Protection Sliding Doors(4BAR)
Blast Sliding Door (U.S.ARMY Kunsan Airport 8th Fleet of USFK)
Igloo Blast Sliding Door - US Army ECMs in AHA No. 25 Camp Casey Project (7 BAR)
Igloo Blast Sliding Door - US Army ECMs in AHA No. 25 Camp Casey Project (7 BAR)
The US Japan Armed Forces FED / Stainless Steel Door / Typhoon rate / 7.65KPa
Blast Proof Door( India project )
Magazine Project(100bar)
NCD MCR Entrance
EMBEDD PLATE
Turkmenistan President Palace Project(12 BAR)
CP-Tango Project (Max. 35 BAR)
Cladding Project Site(15,000mm x 6,200mm, 30 BAR)
Double Swing Blast Door (Project B-FM Phase In Singapore(36 BAR, 6.0M x 5.5M))
Custom Blast Doors-(CBR) Vertical Load Acting(363Psi) 4.0M x 8.0m)
Blast & Gas Tight Door(8.0 bar/ASTM E 283)/ SEONGNAM City Hall CBRNe Facilities
Nuclear Power Plant
Steel Type Blast & Air Leakage Door
Steel Type Blast & Air Leakage Door
Wolsung Nuclear Power Plant
Performance Valuation Test of Blast Door
Performance Valuation Test of Blast Door
Erection of Blast Door Ulchin Nuclear Power Plant 3&4
Steel Type Blast Door(3Bar) NBC Shelter Ground Facility at 94-5951
Concrete Type Blast proof door
Concrete Type Blast Door(3Bar): Daejeon City Hall at NBC Shelter
OIL, LNG Part
PEMEX INATITLAN ALKYLATION in Mexico (12.5 PSI)
Blast Proof Door 30kpa(SAKHALIN II PROJECT PHASE2-LNG PLANT)
Blast Proof Door( India project )
Hyundai Oilbank PCD EntranceAuto/Manual Type Blast Door(3Bar)
S-OIL (Onsan Factory) NHC Blast Door (7.8psi)
Blast Window2.02 psi Pressure & 1 hr Fire rate
Fire & Blast Proof Door Kuwait Oil (2hr Fire-Rate)